The Thermalert® MP50™ Process Imager
Provides accurate temperature image data of moving
objects. This multi-point measurement is achieved by a
rotating optical system which collects infrared radiation
at 256 points within a 90° field-of-view. The motorized
mirror scans at 48 lines per second (without analog output),
and the unique internal blackbody system calibrates the
sensor on every scan. An internal high speed microprocessor
calculates the temperature of the individual measurement
points which are then compared to process setpoints for
each of three userdefined sectors. The MP50 comes standard
with air purging and water cooling, three configurable
analog outputs, and two-way digital communications. MP50
Process Imager models are available with a choice of temperature
and spectral ranges. The plastics models (P3 and P7) provide
temperature measurement on thin plastic film. The glass
model (G5) ensures process quality on flat glass, glass
windshields, and tempering lines. The 1M model for metals
has a 45° field-of-view, allowing the scanner to be
safely mounted away from hot targets.
|
- Fast scan speed, up to 48 lines
per second
- Real-time color profiles with
DataTemp MP software
- Automatic calibration
- 40,000 MTB brushless motor
- Three user-configurable 4-20
mA outputs for heater zone control
- Two-way digital communications
for remote monitoring and control
- Built-in air purge keeps window
free of dirt, dust, and condensation
- Rugged, die cast housing (waterproof)
for harsh, industrial environments
- Fast baud rate allows users to
see complete thermal image of their process
- RS-485 communications support
data transmission up to 1000 m (3000 ft.)
- Built-in water cooling permits
installation in ambient temperatures up to 180°C
(355°F)
- Choice of models for specialized
applications
- Additional protective enclosures
(stainless steel) available
|
| System
accuracy: |
(0 to 50°C (32 to 122°F) ambient, mid of measurement
range) |
| Optical
Scan Rate / System Response Time: |
48
Hz / 21 msec, Analog Outputs inactive 36
Hz / 28 msec, Analog Outputs active |
| Scan
Angle, FOV : |
90°
(45° for 1M model) |
| Focus: |
1.52
m (60 in.) std, (custom focuses available) |
| Emissivity: |
0.1
to 1.0 digitally adjustable |
| Signal
Processing : |
MAX,
MIN, AVG, Peak/Valley Hold, Alarm setpoints |
| Output
(Analog): |
3
user-definable current outputs, each freely adjustable |
| Input: |
Trigger
(+ 5 VDC pulse), RS-232/RS-485 |
| Power
Supply : |
24
VDC ± 25%, 1 A |
| Environmental
Rating |
NEMA-12
(IEC 529, IP 65) |
| Ambient
Operating Range: |
Without
water cooling 0° to 50°C (32 to 122°F),
With water
cooling Max 180°C (356°F)
|
| Relative
Humidity : |
10
to 90 %, non condensing |
| Shock: |
IEC
68-2-29, 3 axes, 1000 bumps |
| Vibration: |
IEC
68-2-6, 3 axes, 10 to 150 Hz |
| During
Operations: |
0.5
G, non-operating: 2 G |
| Scan
Motor: |
MTBF
40,000 hours |
|